<?xml version="1.0" encoding="utf-8" standalone="yes"?>
<rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom">
  <channel>
    <title>Feldbinder Trailer Service &amp; Repair Poland – TDT | feldbinder.pl on Feldbinder Trailer Service &amp; Repair – Chorula Poland | feldbinder.pl</title>
    <link>https://feldbinder.pl/en/</link>
    <description>Recent content in Feldbinder Trailer Service &amp; Repair Poland – TDT | feldbinder.pl on Feldbinder Trailer Service &amp; Repair – Chorula Poland | feldbinder.pl</description>
    <generator>Hugo</generator>
    <language>en</language>
    <lastBuildDate>Wed, 20 May 2026 00:00:00 +0000</lastBuildDate>
    <atom:link href="https://feldbinder.pl/en/index.xml" rel="self" type="application/rss+xml" />
    <item>
      <title>Feldbinder EUT Outlet Valve &amp; Seals – When to Replace</title>
      <link>https://feldbinder.pl/en/blog/feldbinder-outlet-valve-seals-replacement/</link>
      <pubDate>Wed, 20 May 2026 00:00:00 +0000</pubDate>
      <guid>https://feldbinder.pl/en/blog/feldbinder-outlet-valve-seals-replacement/</guid>
      <description>&lt;h2 id=&#34;in-brief&#34;&gt;In Brief&lt;/h2&gt;&#xA;&lt;p&gt;&lt;strong&gt;Feldbinder EUT outlet valve and seals&lt;/strong&gt; — discharge spout DN100/DN150 with EPDM, PTFE or silicone seal, bottom discharge valve or butterfly valve. Signs of wear: material leakage at the spout, resistance when closing under load, product traces outside the tank. Seal replacement: 2–4 hours. Seal material depends on cargo: EPDM for plastics granules, PTFE for food/pharma, food-grade silicone for dry food. Preventive replacement every 3 years (2 years for food service). PHS Magnum stocks Feldbinder parts, issues service protocol for TDT.&lt;/p&gt;</description>
    </item>
    <item>
      <title>Feldbinder EUT vs KIP Trailer – Structural Differences, Uses and Service</title>
      <link>https://feldbinder.pl/en/blog/feldbinder-eut-vs-kip-differences/</link>
      <pubDate>Wed, 20 May 2026 00:00:00 +0000</pubDate>
      <guid>https://feldbinder.pl/en/blog/feldbinder-eut-vs-kip-differences/</guid>
      <description>&lt;h2 id=&#34;in-brief&#34;&gt;In Brief&lt;/h2&gt;&#xA;&lt;p&gt;&lt;strong&gt;Feldbinder EUT and KIP are two fundamentally different bulk trailer types&lt;/strong&gt; — EUT is a horizontal pneumatic silo with an aerating floor in food-grade stainless steel; KIP is a hydraulic tipping body with gravity discharge. They differ in tank material, unloading principle, typical cargo and service requirements. PHS Magnum in Chorula services both: stainless steel welding and valve overhaul for EUT; hydraulic cylinder and hinge repair for KIP.&lt;/p&gt;</description>
    </item>
    <item>
      <title>Feldbinder Tank Cleanliness Certificate – When Required and How to Get One</title>
      <link>https://feldbinder.pl/en/blog/feldbinder-tank-cleanliness-certificate/</link>
      <pubDate>Wed, 20 May 2026 00:00:00 +0000</pubDate>
      <guid>https://feldbinder.pl/en/blog/feldbinder-tank-cleanliness-certificate/</guid>
      <description>&lt;h2 id=&#34;in-brief&#34;&gt;In Brief&lt;/h2&gt;&#xA;&lt;p&gt;&lt;strong&gt;Feldbinder tank cleanliness certificate&lt;/strong&gt; — a documentation package required by food, pharmaceutical and chemical shippers when registering a trailer for food-contact service. Core requirements: Ra ≤ 0.8 µm inner surface (profilometer measurement), passivation protocol, ATP test, seal material certificates (EC 1935/2004 / FDA 21 CFR). Mandatory after every welding repair, at TDT inspection, and at food shipper registration. PHS Magnum in Chorula performs the full procedure and issues the complete documentation set.&lt;/p&gt;</description>
    </item>
    <item>
      <title>Feldbinder Trailer Maintenance: EUT and KIP Service Guide</title>
      <link>https://feldbinder.pl/en/blog/feldbinder-trailer-maintenance-guide/</link>
      <pubDate>Wed, 08 Apr 2026 00:00:00 +0000</pubDate>
      <guid>https://feldbinder.pl/en/blog/feldbinder-trailer-maintenance-guide/</guid>
      <description>&lt;h2 id=&#34;in-brief&#34;&gt;In Brief&lt;/h2&gt;&#xA;&lt;p&gt;&lt;strong&gt;Feldbinder silo trailer maintenance&lt;/strong&gt; — two fundamentally different systems: EUT (horizontal, pneumatic discharge via aeration pads) and KIP (hydraulic tipping, gravity discharge). EUT food-grade stainless: Ra ≤ 0.8 µm (ISO 4287) and passivation certificate required at every TDT inspection. KIP: hydraulic oil change every 12 months, pivot joint inspection every 6 months — leaking hydraulic cylinder = immediate out-of-service. TDT inspection: every 2 years for both types. PHS Magnum services EUT, KIP and stainless food trailers with full documentation (Ra protocol, passivation, PT report). DACH operators: invoicing in EUR, German documentation available.&lt;/p&gt;</description>
    </item>
    <item>
      <title>Feldbinder TDT Inspection: Stainless Steel Food Trailer Guide</title>
      <link>https://feldbinder.pl/en/blog/feldbinder-tdt-inspection-stainless-steel/</link>
      <pubDate>Tue, 03 Mar 2026 00:00:00 +0000</pubDate>
      <guid>https://feldbinder.pl/en/blog/feldbinder-tdt-inspection-stainless-steel/</guid>
      <description>&lt;h2 id=&#34;in-brief&#34;&gt;In Brief&lt;/h2&gt;&#xA;&lt;p&gt;&lt;strong&gt;Feldbinder TDT inspection — stainless steel food trailers&lt;/strong&gt; require mandatory periodic inspection every 2 years under PED 2014/68/EU. Additional requirements vs aluminium: Ra ≤ 0.8 µm certificate (ISO 4287), passivation certificate (ASTM A380), EC 1935/2004 seal compliance. Our pre-inspection package covers interior cleaning, Ra measurement, passivation (HNO₃ 30 % or Avesta 401 gel), PT weld inspection, seal replacement, and full documentation. TDT certificates issued in Poland are valid in all EU member states. DACH operators: 180 km from German border, invoicing in EUR, German documentation on request.&lt;/p&gt;</description>
    </item>
    <item>
      <title>Stainless Steel Passivation on Feldbinder Trailers: Why and How</title>
      <link>https://feldbinder.pl/en/blog/feldbinder-stainless-steel-passivation/</link>
      <pubDate>Tue, 10 Feb 2026 00:00:00 +0000</pubDate>
      <guid>https://feldbinder.pl/en/blog/feldbinder-stainless-steel-passivation/</guid>
      <description>&lt;h2 id=&#34;in-brief&#34;&gt;In Brief&lt;/h2&gt;&#xA;&lt;p&gt;&lt;strong&gt;Stainless steel passivation on Feldbinder trailers&lt;/strong&gt; — the Cr₂O₃ passive layer is destroyed by welding, iron-tool grinding, and chlorides. Without it: rust within weeks, rejection at food factories, TDT failure, voided insurance. Method 1: HNO₃ 30 % at 20–50 °C for 20–30 minutes. Method 2: Avesta 401 gel for welds (30–60 min). Ra ≤ 0.8 µm (ISO 4287) required for food contact surfaces — verified with calibrated profilometer. Passivation is mandatory after every welding repair. PHS Magnum issues a full documentation package: passivation certificate + Ra protocol.&lt;/p&gt;</description>
    </item>
    <item>
      <title>Contact – Feldbinder Trailer Service</title>
      <link>https://feldbinder.pl/en/kontakt/</link>
      <pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
      <guid>https://feldbinder.pl/en/kontakt/</guid>
      <description>&lt;h2 id=&#34;contact-us&#34;&gt;Contact us&lt;/h2&gt;&#xA;&lt;p&gt;&lt;strong&gt;PHS Magnum s.j.&lt;/strong&gt;&lt;br&gt;&#xA;ul. Koscielna 9, 47-316 Chorula, Poland&lt;/p&gt;&#xA;&lt;p&gt;&lt;strong&gt;Phone:&lt;/strong&gt; &lt;a href=&#34;#ZgotmplZ&#34;&gt;+48 602 716 551&lt;/a&gt;&lt;br&gt;&#xA;&lt;strong&gt;E-mail:&lt;/strong&gt; &lt;a href=&#34;mailto:biuro@magnumchorula.pl&#34;&gt;biuro@magnumchorula.pl&lt;/a&gt;&lt;/p&gt;&#xA;&lt;p&gt;&lt;strong&gt;Working hours:&lt;/strong&gt; Mon–Fr 06:00–20:00 | Sat 07:00–15:00&lt;/p&gt;&#xA;&lt;p&gt;Location: 4 km from A4 motorway, 180 km from German border.&lt;/p&gt;</description>
    </item>
    <item>
      <title>Privacy Policy &amp; Cookies</title>
      <link>https://feldbinder.pl/en/polityka-prywatnosci/</link>
      <pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
      <guid>https://feldbinder.pl/en/polityka-prywatnosci/</guid>
      <description>&lt;h2 id=&#34;data-controller&#34;&gt;Data Controller&lt;/h2&gt;&#xA;&lt;p&gt;&lt;strong&gt;Przedsiębiorstwo Handlowo-Spedycyjne „Magnum&amp;quot; s.j.&lt;/strong&gt; (PHS Magnum), ul. Kościelna 9, 47-316 Chorula, Poland, VAT no. PL 118-00-31-119, KRS: 0000028276, e-mail: &lt;a href=&#34;mailto:biuro@magnumchorula.pl&#34;&gt;biuro@magnumchorula.pl&lt;/a&gt;.&lt;/p&gt;&#xA;&lt;h2 id=&#34;what-data-we-collect-and-why&#34;&gt;What data we collect and why&lt;/h2&gt;&#xA;&lt;h3 id=&#34;contact-form&#34;&gt;Contact form&lt;/h3&gt;&#xA;&lt;p&gt;We collect name or company, e-mail, phone and message, solely to respond to service or offer enquiries.&lt;/p&gt;&#xA;&lt;p&gt;&lt;strong&gt;Legal basis:&lt;/strong&gt; Art. 6(1)(b) GDPR. &lt;strong&gt;Retention:&lt;/strong&gt; 3 years from last contact.&lt;/p&gt;&#xA;&lt;h3 id=&#34;analytics--cookies&#34;&gt;Analytics &amp;amp; cookies&lt;/h3&gt;&#xA;&lt;p&gt;Google Analytics (via Google Tag Manager) — only activated after consent (Art. 6(1)(a) GDPR). Withdraw via cookie banner at bottom of page.&lt;/p&gt;</description>
    </item>
  </channel>
</rss>
