In Brief
Feldbinder TDT inspection — stainless steel food trailers require mandatory periodic inspection every 2 years under PED 2014/68/EU. Additional requirements vs aluminium: Ra ≤ 0.8 µm certificate (ISO 4287), passivation certificate (ASTM A380), EC 1935/2004 seal compliance. Our pre-inspection package covers interior cleaning, Ra measurement, passivation (HNO₃ 30 % or Avesta 401 gel), PT weld inspection, seal replacement, and full documentation. TDT certificates issued in Poland are valid in all EU member states. DACH operators: 180 km from German border, invoicing in EUR, German documentation on request.
Feldbinder TDT Inspection for Stainless Steel Silo Trailers
Feldbinder silo trailers operating as pressure vessels require mandatory TDT (Transportowy Dozór Techniczny) periodic inspections under Polish law and EU Directive PED 2014/68/EU. Stainless steel food-grade trailers have additional hygiene documentation requirements.
Inspection Schedule
| Type | Frequency |
|---|---|
| Periodic inspection | Every 2 years |
| Extended inspection + pressure test | Every 6 years |
| Post-repair inspection | After any welding on the pressure vessel |
| Post-accident inspection | After any structural damage |
Additional Requirements for Food-Grade Stainless Steel
Unlike aluminium silo trailers, stainless steel food trailers must demonstrate:
- Surface roughness — Ra ≤ 0.8 µm on all food-contact surfaces (ISO 4287 measurement protocol)
- Passivation certificate — intact Cr₂O₃ layer on all stainless steel surfaces (ASTM A380)
- Cleaning protocol — use of EC 1935/2004 compliant cleaning agents, pH-neutral residue-free
- Seal compliance — FDA 21 CFR and EC 1935/2004 for EPDM and silicone seals
Our Pre-Inspection Preparation Service
We prepare Feldbinder trailers for TDT inspection:
- Interior cleaning — alkaline wash + deionised water rinse
- Ra measurement — instrument measurement of all surfaces, written protocol for inspector
- Passivation — HNO₃ 30 % or Avesta 401 gel if passivation layer is compromised
- PT weld inspection — dye penetrant testing of all internal weld seams (EN ISO 3452)
- Seal replacement — dome seals, discharge port seals, all FDA-grade
- Safety valve recertification — with calibration certificate
- Pressure test — 1.0 × or 1.25 × MOP depending on inspection type
- Document package — Ra protocol, passivation certificate, PT report, repair logs
After the Inspection
- TDT certificate valid for 2 or 6 years
- Ra measurement protocol
- Passivation certificate
- PT weld inspection report
- Updated trailer service book
- Next inspection date sticker
For German Operators
Our service centre in Chorula is 180 km from the German border and 4 km from motorway A4. We serve German, Austrian and Swiss operators with:
- All documentation available in German on request
- Invoicing in EUR
- Mobile service available (we come to your yard)
Related: Feldbinder trailer service · Spare parts · TDT inspection · Repair & renovation